measurement of polyacrylamide polymers in water and ...

Measurement of polyacrylamide polymers in water and ...

本研究提出了一种使用可生成实时数据的在线紫外-可见分光光度计定量聚丙烯酰胺浓度的方法。 七种聚合物的吸光度光谱在 191.5-750 nm 的波长范围内建立,所有聚合物的最高吸光度记录在 191.5 nm。 聚合物的紫外吸光度在 191.5-240 nm 之间逐渐降低,并且在 191.5、200 和 210 nm 处的浓度和吸光度之间存在强线性关系 (R 2 > 0.97)。 在蒸馏水和从水和废水处理厂收集的其他四个样品中建立了检测限。 聚合物化学以及有机和无机杂质的存在会影响检测限。 在蒸馏水样品中,测得的最低检测限为 0.05 mg/L。 在从水和废水处理厂收集的样品中,检测限在 0.07 和 1.35 mg/L 之间变化,具体取决于聚合物类型和水质。

Get Price
measurement of polyacrylamide polymers in water and ...

Measurement of polyacrylamide polymers in water and ...

This document discusses a study that presents a method for quantifying polyacrylamide concentration in water and wastewater samples using an in-line UV-vis spectrophotometer. The researchers established absorbance spectra for seven polymers between 191.5-750 nm and found the highest absorbance at 191.5 nm for all polymers.

Get Price
 ... measurement of molecular weight distribution of polyacrylamides in ...

... Measurement of Molecular Weight Distribution of Polyacrylamides in ...

G.Eudoxie and S.E. Hitlal: Efficiency of Polyacrylamide Polymers in Settling Aggregate Mining Tail Water 62 Particle size distribution of the tail water is illustrated in Figure 1. According to the ISSS Classification, clay size particles (<2 µm) account for 54 % of the

Get Price
impact of cationic polyacrylamide degradation on flocculatio ...

Impact of cationic polyacrylamide degradation on flocculatio ...

Measurement of polymers in water and wastewater is a major challenge, and there is currently no quick and simple method that can achieve this. This study presents a method for quantification of polyacrylamide concentration using an in-line UV–vis spectrophotometer that can generate real-time data. Absorbance spectra of seven polymers were established in the wavelength range of 191.5–750 nm ...

Get Price
long-term stability prediction of polyacrylamide-type polyme ...

Long-term stability prediction of polyacrylamide-type polyme ...

intrinsic viscosities of the polyacrylamides using Ubbelohede viscometer, no. 4809 ASTM at 25 ± 0.1ºC. The polyacrylamide solutions were prepared in distilled water. The intrinsic viscosity calculations were made for polyacrylamide after filtration through 250

Get Price
quantification of polymer concentration in water - ...

QUANTIFICATION OF POLYMER CONCENTRATION IN WATER - ...

16 of polymer concentrations in water samples as well as in centrate samples collected from a 17 wastewater treatment plant. 18 Keywords: polymer, concentration, measurement, UV-vis absorbance, water.

Get Price
rheology of polyacrylamide-based fluids and its impact on ...

Rheology of polyacrylamide-based fluids and its impact on ...

Thus, capillary viscometery gives only a relative measure of the viscosity and not an absolute one. Let us define a couple of terms before proceeding. Specific viscosity = hsp = hc - 1 (2) hs hc Intrinsic viscosity = h = lim hsp c c= lim 1 ln (3) cÆ0 cÆ0 hs

Get Price
synthesis and conductivity measurement of polyacrylamide in ...

Synthesis and Conductivity Measurement of Polyacrylamide in ...

Polyacrylamide was synthesized from its monomer by plasma polymerization technique. The polymer so formed is in nano state and was confirmed by IR, UV and SEM tech-niques. Conductivities were determined from 30 to 200 ºC with a frequency ranges from

Get Price
(pdf) polyacrylamide for wastewater treatment - researchgate ...

(PDF) Polyacrylamide for wastewater treatment - ResearchGate ...

from 1 USD and more Al Momani, F. A., & Örmeci, B. (2014). Measurement of polyacrylamide polymers in water and wastewater using an in-line UV–vis spectrophotometer.

Get Price
revision on the titration method for accurately measuring th ...

Revision on the Titration Method for Accurately Measuring th ...

measurement, titration method, revision 1 Corresponding author: tel.: 86-510-85912520; fax ... ing of polyacrylamide products if the content of residual AM exceeds 0.5%[7]. Therefore, the content ...

Get Price
quantification of polymer concentration in water using uv-vi ...

Quantification of polymer concentration in water using UV-Vi ...

Materials and Apparatus: Polyacrylamide synthesized in experiment 1. Water containing 0.05 M NaN0 3 + 0.02% NaN 3 Water bath with arrangements for maintaining constant temperature. Brief Background: Methods to measure viscosity of polymer solutions: (See handout from Rabek, Experimental Methods in Polymer Science, Ch 9.) ...

Get Price
1.3: conversion of polyacrylamide to sodium polyacrylate and ...

1.3: Conversion of Polyacrylamide to Sodium Polyacrylate and ...

Materials and Apparatus: Polyacrylamide synthesized in Experiment #1. Water solution of NaOH (100g NaOH in a liter of solution) Calcium chloride (1M) HCl 0.05 M NaNO 3 + 0.02% NaN 3 Stoppered or capped flasks Receiving flask 0.2 and 0.45 micron Millex

Get Price
[pdf] development of a flow injection analysis method for the ...

[PDF] Development of a flow injection analysis method for the ...

DOI: 10.1016/S0920-4105(98)00042-4 Corpus ID: 62809386 Development of a flow injection analysis method for the determination of acrylamide copolymers in brines @article{Taylor1998DevelopmentOA, title={Development of a flow injection analysis method for the determination of acrylamide copolymers in brines}, author={Kevin C. Taylor and R. A. Burke and Hisham A. Nasr-El-Din and Laurier Lincoln ...

Get Price
al momani, f.a. and örmeci, b. (2014) measurement of po ...

Al Momani, F.A. and Örmeci, B. (2014) Measurement of Po ...

Al Momani, F.A. and Örmeci, B. (2014) Measurement of Polyacrylamide Polymers in Water and Wastewater Using an In-Line UV-Vis Spectrophotometer. Journal of Environmental Chemical Engineering, 2, 765-772.

Get Price
a method for measuring the degree of anionicity of polyacryl ...

A method for measuring the degree of anionicity of polyacryl ...

tolerate ionic strengths up to 3M. Using 1-ml samples of 10-ppm pure tagged polymer solutions in the absence of adsorption, the polyacrylamide polymer (P AM) gave 178 cpm and the copolymer containing the sulfonate, P AMS, gave ISO cpm. modified.

Get Price

Can a UV spectrophotometer measure polyacrylamide concentration?

This study presents a method for quantification of polyacrylamide concentration using an in-line UV–vis spectrophotometer that can generate real-time data. Absorbance spectra of seven polymers were established in the wavelength range of 191.5–750 nm and the highest absorbance was recorded at 191.5 nm for all polymers.

How to determine acrylamide based polymer concentration?

Many methods have been reported on the determination of acrylamide-based polymer concentrations [ ], including nitrogen-measurement method, nitrgon-bromination method, turbidimetry method, gel permeation chromatography method, viscosity measurement,

How to determine polyacrylamide concentration based on nitrogen digestion method?

Nitrogen digestion method was set up to determine polyacrylamide concentrations based on the measurement of nitrogen content in the polymer solution that is in proportion to the polymer concentration ( Chen et al., 2016).

Do polyacrylamide polymers absorb light?

The results from this study indicate that polyacrylamide polymers used for water and wastewater treatment strongly absorb light in the 191.5–230 nm wavelength range, and the peak absorbance was measured at 191.5 nm for all of the seven polymers tested in this study.

Are polyacrylamides toxic?

Although the polymers are relatively nontoxic, for health concerns, the use of polyacrylamides especially in drinking water and also wastewater has been subjected to closer evaluation during the last decade.

What is the rate of polyacrylamide polymerization?

According to Lin, the rate of polyacrylamide polymerization was reported to be very low at temperature < 45 ° C. The rate of polymerization increased with the temperature due to the increasing rate of primary free radicals production that initiated the polyacrylamide polymerization .